This paper focuses on several aspects of the electric potential variation in pure water and cryoprotective agent solutions during solidification. The results of the experiments show that voltages while frozen in cryoprotective agent solutions vary more slowly and stedily than in pure water. The mechanism of the effect of the cryoprotective agent is also discussed.