Abstract:This paper describes an interferometric system. The spacial position of a prism can be determined with the naked eye by measuring the change of the direction of the interference fringe system. With the help of a precise angle-measuring device, the apex angle and the minimum deviation angle of the prism can be measured; hence the optical refractive index of the glass. This device is simple to construct, rapid to manipulate and of high precision.