Abstract:In this paper, the two-phase critical flow in a refrigerant capillary tube is theoretically investigated. On the basis of two-phase slip model, a model of critical flow is established. The mechanism concerning two-phase critical flow is studied. The experimental results are fully in agreement with the conclusion reached in this article.