Abstract:On the basis of the experimental analysis,it is pointed out that the throttle tubes possess distinguishing measuring characteristics when the Reynolds Number is greater than 5 000. The discharge coefficient model of throttle tubes is derived from Bernoulli and the continuity equations. Good agreement is found between the discharge coefficient model and the experimental results. The mean square errors are within 2%.