Abstract:The effects of geometric parameters on the performance of a single nozzle eductor/diffuser system are analyst numerically. The numerical results are in good agreement with the experimental ones. Analysis shows that there is a scope of geometric parameters in which the eductor/diffuser system will attain its high performance. This research will be valuable to the design of high performance eductor/diffuser system.