The parellel light beam measurement and analysis system was designed and manufactured for studying kinematics of the whole lumbar spine. The movement of three marks, which fixed in vertebrae, were separately projected on the screen of the system. These light marks were recorded by video camera and sent to image processing system. According to the principle of rigid body kinematics three-dimensional motion of light marks were calculated and the kinematic characteristics of the whole lumbar spine were obtained.