Abstract:The application of equal mass flow method in high temperature recuperator test system is discussed.The heat transfer performance of recuperator is investigated,and the heat transfer data are analyzed.The convective heat transfer coefficient h is calculated from total heat transfer coefficient by use of equal mass flow method (modified equal Reynolds number method),and the Nu-Re dimensionless equation which is of engineering application value is obtained.