The structural analysis model of the up channel with jacket and insulation was established based on the finite element analysis software ANSYS.According to the operation conditions,the temperature and pressure were loaded to obtain the stress in the equipment.The stress intensity and fatigue life were assessed respectively to ensure that the equipment meets the requirements of static strength and fatigue life referring to the standard JB4732.